You're currently viewing an old version of this dataset. To see the current version, click here.

Particulate trace elements (Al, Ti, V, P, Fe, Mn, Co, Ni, Cu, and Cd) measured on water bottle samples from ultra clean CTD/Water sampler-system during POLARSTERN cruise PS100 / GN05

This dataset contains measured labile particulate and total particulate trace element concentrations (Al, Ti, V, P, Fe, Mn, Co, Ni, Cu, and Cd) of water bottle samples collected during GEOTRACES expedition GN05 (PS100) between 21 July and 1 September 2016 on Northeast Greenland Shelf. Samples were collected using the ultra-clean CTD rosette, equipped with 24 × 12 L GoFlo bottles following GEOTRACES sampling protocols (Cutter et al., 2017; https://www.geotraces.org). Particulate TM samples were collected onto pre-acid leached Polyethersulfone (PES) Membrane filters (0.2 µm, Sartorius) with 1.2 - 4.1 L of seawater filtered per sample. Labile particulates were determined after applying a weak acid leach with a mild reducing agent and a short heating step with a total leach time of 2 h. Total particulates were then analyzed following a 15 h reflux digest at 150 °C using a mixture of hydrofluoric acid and nitric acid. The validation of labile and total particulate trace metal analyses was monitored by reference materials BCR-414 and PACS-3. Information on the analytical procedure including reference materials and limits of detection can be found in related published manuscripts. The concentrations reflect the mean and the corresponding uncertainty is calculated as the standard deviation to replicate measurements. Uncertainty is calculated as one standard deviation (1σ, STD) to replicate measurements via ICP-MS. Use of quality flags (QF) according to GEOTRACES policy (https://www.geotraces.org/geotraces-quality-flag-policy/).

Data and Resources

This dataset has no data

Cite this as

Al-Hashem, Ali A, Achterberg, Eric Pieter, Krisch, Stephan, Lodeiro, Pablo Fernandez, Chen, Xue-Gang (2022). Dataset: Particulate trace elements (Al, Ti, V, P, Fe, Mn, Co, Ni, Cu, and Cd) measured on water bottle samples from ultra clean CTD/Water sampler-system during POLARSTERN cruise PS100 / GN05. https://doi.org/10.1594/PANGAEA.948466

DOI retrieved: 2022

Additional Info

Field Value
Imported on November 30, 2024
Last update November 30, 2024
License CC-BY-4.0
Source https://doi.org/10.1594/PANGAEA.948466
Author Al-Hashem, Ali A
Given Name Ali A
Family Name Al-Hashem
More Authors
Achterberg, Eric Pieter
Krisch, Stephan
Lodeiro, Pablo Fernandez
Chen, Xue-Gang
Source Creation 2022
Publication Year 2022
Resource Type text/tab-separated-values - filename: PS100_tracemetal
Subject Areas
Name: Atmosphere

Name: Ecology

Name: Lithosphere

Related Identifiers
Title: Dissolved, Labile, and Total Particulate Trace Metal Dynamics on the Northeast Greenland Shelf
Identifier: https://doi.org/10.1029/2022GB007528
Type: DOI
Relation: References
Year: 2022
Source: Global Biogeochemical Cycles
Authors: Chen Xue-Gang , Krisch Stephan , Al-Hashem Ali A , Hopwood Mark James , Rutgers van der Loeff Michiel M , Huhn Oliver , Lodeiro Pablo Fernandez , Steffens Tim , Achterberg Eric Pieter .